If you need to know about batteries; you’ve come to the right place 点击这里访问我们的中文网站

backup power

Himoinsa unveils HVW480 crane-integrated genset

Tue, 02/05/2013 - 17:36 -- Anonymous
Share page with AddThis

Spanish genset OEM Himoinsa has unveiled the HVW480, a genset specially designed for integration into mobile cranes.

Last June, Himoinsa reached an agreement with Paceco Espana, a company that designs and manufactures cranes and container shipment & handling systems, to supply power to five RTT Transtainer cranes in the Port of Tenerife.

After several months of work, the Power Solution engineering team of Himoinsa designed the HVW480 generating set. Features of the EU stage IIIA-compliant HVW480 genset include: a fastening system to prevent detachment caused by crane movement; correctly dimensioned for loads with high harmonic distortion and load variations during aggressive work cycles; and paint and hardware treatment, suitable for working in saline environments at seaports.

The crane incorporates a fuel-saving system, so that during waiting time until vehicles arrive to load or unload goods, the system automatically reduces the revolutions of the diesel group to minimum tick over speed, resulting in fuel saving. 

 

Wind farm battery to restart following shut down

Tue, 02/05/2013 - 17:36 -- Anonymous
Share page with AddThis

An experimental wind farm project that has been on hold for more than a year is due to restart. Xcel Energy’s 1MW sodium-sulphur battery bank in Minnesota, US, was put out of action amid safety fears when a similar battery caught fire in Japan.

Fear of a similar fire meant the $4.7 million sodium-sulphur battery bank, and others made by Japanese firm NGK Insulators, were shut down in September 2011.

The cause of the fire was found to be a faulty cell that had leaked molten material and triggered a short-circuit. The battery at the site in Minnesota experienced no problems in its two-year working history and is due to be operational again in February 2013.

When the site is operational again it can continue the long-term trial of the viability of wind energy storage. The site has 20 50kW battery modules capable of storing 7.2MWh of electricity.

 

Aggreko kept some lights on at Super Bowl

Mon, 02/04/2013 - 17:36 -- Anonymous
Share page with AddThis

Aggreko provided 13MWs of power to the 2013 Super Bowl at the New Orleans Mercedes-Benz Superdome. There is a lesson to be learned about the importance of backup provisions following the much talked about low-light of this year’s American football clash - the power cut in the second half.

Aggreko provided back up power for the halftime show and to the designated press areas for national and international broadcasters aas well as to VIP sections – resulting in no disruption in these areas.

The problem was with the stadium power, provided Entergy, which had no back up power supply. In a statement Entergy said the problem related to a piece of equipment monitoring the electrical load detected a system abnormality and caused the power to be cut off.

This high profile power outage lasted 35 minutes, and halted the game until the problem was fixed.

Emerson offer double protection for UPS

Fri, 02/01/2013 - 17:36 -- Anonymous
Share page with AddThis

Emerson Network Power has announced a feature to make industrial UPSs twice as secure. Data from the UPS is fed into the AMS Suite Intelligent Device Manager to provide continuous monitoring of critical systems. This will benefit oil and gas terminals, power generators and offshore facilities and other plants where predictive maintenance is required.

The UPS can generate and broadcast self-diagnostic data, which the Intelligent Device Manager can pick up and feed back to the plant manager to inform them of any deterioration of parts to the UPS, or in the event of failure, to ensure downtime is prevented.

David Vasselin, Vice President of business development at Emerson Network Power said: "This is cost-effective insurance against an unexpected power outage where losses can run into the millions of dollars per day."

The system seamlessly provides information on UPS performance, and issues alerts should the performance of any part fall below what is expected, this tells the plant manager where maintenance is needed and how urgently.

Finning bags engine deal for North Sea oil & gas platform

Fri, 02/01/2013 - 17:36 -- Anonymous
Share page with AddThis

SPP Pumps has selected Finning to supply two custom Cat 3512C HD engines to drive firewater pumps for the UK North Sea’s ATP Cheviot oil and gas production platform – a semi-submersible drilling, production and storage facility due for completion in 2013.

The Cat marine engines, rated at 1678 kW at 1800 rpm, are packaged with accessories by Finning to meet both the client’s specification and the stringent requirements of NFPA 20, the National Fire Protection Association standard.  This is to ensure the engines will deliver reliable power in the event of a fire emergency.

These refinements required a number of modifications to the engine controls to meet NFPA 20. The engine rating is approved by the American Bureau of Shipping (ABS) as required for the floating platform.  This, in particular, meant that Finning had to design the engine package to maintain operation at a constant 22.5-degree tilt in the event of an emergency, such as the platform losing buoyancy.

Each firewater pump engine is certified to EPA marine tier two classification and meets the E3 emissions’ test cycle for marine applications.  NFPA requirements also specified the addition of a dual engine control module (ECM) so that, in the unlikely event of failure of the main ECM, the second module will maintain the engine systems and performance will be unaffected.

Tognum unveils genset exhibits for Bauma 2013

Fri, 02/01/2013 - 17:36 -- Anonymous
Share page with AddThis

German genset OEM Tognum is to showcase diesel gensets carrying the MTU Onsite Energy brand at the Bauma construction machinery exhibition in Munich from 15-21 April 2013.

The gensets will be displayed in the open-air area (45A, booth 106) and include a hooded genset based on a 12V 1600 engine with 660 kVA power output, suitable for open-air use on building sites.

The genset hood is both sound and weather-proof and protects the genset from weather influences and contamination while reducing noise emissions.

Also on display is an MTU Onsite Energy genset based on a 16V 4000 engine with 2,595 kVA power output.

Source UPS appoints David Gould as business development manager

Fri, 02/01/2013 - 17:36 -- Anonymous
Share page with AddThis

UK Uninterruptible Power Supply specialist Source UPS has announced the appointment of David Gould to the role of Business Development Manager.

Mr Gould has more than 15 years of experience in the IT industry and has worked for several top-tier UPS power supply distributors, including seven years with Bell Micro (now Avnet Technologies) as APC product manager.

His expertise is in handling large UPS and data centre projects and working with some of the most recognised brands and corporations in the world. Reporting to managing director, Gavin Banks, Mr Gould will be responsible for developing new business with three-phase UPS systems, IT racks and precision cooling solutions in the server room and small data centre markets.

In 2012, Source UPS became a Tripp Lite Critical Application Partner (CAP).

Don'’t let diesel issues bug your critical power

Fri, 02/01/2013 - 17:36 -- Anonymous
Share page with AddThis

For many years, the diesel back-up generator has been a symbol of reliability for data centres, providing the emergency power to keep servers online during utility power outages. Standard data centre design includes an uninterruptible power supply (UPS), which can keep systems running during a mains power cut.

However, equipment will only stay online for the life of the battery in the UPS. For back-up power during an extended outage, a standby generator is the only viable choice. The most important consideration for these environments is to ensure that back-up power is constantly available.

Many data centres invest in standby generators to ensure power, and therefore data, is not lost in the event of a power failure.  With any luck, these machines will last for months, years, or even decades without the need to be used - however, when and if the time comes, it is critical to ensure  they will be fit for purpose.

To ensure this does not happen, many data centre teams and managers will have robust testing and maintenance procedures in place to test the generators, but many neglect to consider a very vital component – the diesel fuel that powers these machines. The contamination of which, can cause generators to fail and millions of pounds of data to be compromised or lost.

With generators sitting stagnant for so long, there is a very real risk that the fuel they run off can become contaminated, so if the machine does ever have to be used in the event of a power failure, it may not do the job it is there to do.

Fuel contamination can come from a number of sources and can include water, acids, resins and gums – all capable of blocking filters. Even something as simple as rainwater getting in to a fuel tank can cause costly damage to equipment, a lengthy cleaning process, and, most worryingly, the failure of a generator that is meant to ensure data is kept secure.

Biodiesel legislation loosens protection

One of the biggest issues in this era of more environmentally friendly bio-diesel fuels is ‘diesel bug’ – a fungus that grows in diesel that can potentially be fatal to the working of generators.

Prior to 2011 legislation that changed the make-up of diesel fuel, high sulphur levels in diesel managed to kill off most of the fungus and bugs, that grow as a result of water contamination, but with the introduction of new legislation on reduced sulphur levels, this 'protection' is no longer there. The bio-diesel blends now widely used for generators are more hydroscopic than old petro-diesel products, meaning it naturally absorbs more water from the atmosphere.

This water contamination means that diesel bug is able to thrive – the use of plant and animal matter used to produce these fuels provides ideal nutrition to the microbes, which can all lead to fuel becoming compromised.

 

The presence of diesel bug in fuel can lead to failures as the biomass they produce can cause blockages of engine filters. This is due to the advent of improved technology, meaning that diesel engine fuel systems now have tighter tolerances and are therefore susceptible to abrasions and blockages, which cause generators to fail.

If diesel bug is detected in fuel, it can be eradicated with the use of a broad spectrum biocide, which acts as an effective antibacterial and antifungal agent to kill the microbes present. However, this will not prevent one of the worst case scenarios from the arrival of diesel bug, commonly known as ‘bio-film’ – a layer of microbes that spreads across the inside of the fuel tank itself as a result of spores released from the fungus in the fuel.

These bio-films then release acid which can corrode fuel tanks, engines and pipes, causing irreparable damage. Even if bio-film is caught before this point, treatment can involve a tank cleaning process, although this can be achieved without removal of the fuel from the tank.

Prevention is better than cure

However, there are a number of ways to overcome these issues, and, as with many problems, prevention is better than cure. The key to maintaining fuel quality and preventing fuel contamination problems, therefore avoiding expensive engine damage, equipment downtime and data loss, is adopting a holistic approach to fuel management and taking care of generator diesel fuel.

The first step towards this is to establish a regular fuel maintenance programme, managed by the generator user with help from companies such as ours, to ensure water and dirt are removed from storage tanks. This will greatly reduce the risk of diesel bug and other detritus that causes breakdowns.

This should include a comprehensive a fuel monitoring programme whereby samples are taken at regular intervals to monitor the condition of fuel - these can then be tested for any impairments or issues, which can then be tackled accordingly before any serious problems are caused. If the beginnings of any issues are identified at this point, simply using fuel additives can be enough to nip the problem in the bud.

However, one of the most important investments you can make to truly ensure that you will have back-up power when you need it most are fuel polishing products. Designed to preserve the quality of stored diesel fuel, they constantly re-circulate fuel through a series of filtration stages removing water and solid particle contamination.

 

Fuel polishing system from IPU

To ensure ease of use for users, these can be made to function automatically, although they should be checked at regular intervals. What this fuel polishing product therefore does is ensure that fuel is kept primed for use when you may need it, reducing the risk of unpredictable failure of critical diesel driven equipment.

With a worldwide shift towards the use of more sustainable or ‘greener’ fuels such as biodiesel, there arrives a raft of new issues for those reliant on generators to keep their intellectual property safe. The serious compromise of fuel can not only cause engine failure, but it can also lead to the need to dispose of contaminated fuel, which defeats the object of switching to greener practices.

Simple tasks undertaken to protect the diesel in generators can not only avoid this, but will also protect the data that you have been entrusted to manage. As a bare minimum we recommend the use of fuel polishing and additives for stored fuel, backed up by the introduction of robust fuel management and testing procedures.

While often overlooked, these small procedures, which are surprisingly time and cost effective, can mean the difference between keeping a data centre safe and a potentially catastrophic loss of power.

Testing Times

Fri, 02/01/2013 - 17:36 -- Anonymous
Share page with AddThis

Facilities managers working in NHS-run hospitals will undoubtedly be familiar with health and safety legislation and guidance surrounding the issue of resilience. Essentially, resilience is the ability of a building and its services to withstand the impact of an incident or emergency. Such emergencies might include acts of terrorism, civil disturbances, storm damage and unplanned interruptions to utility supplies.

Emergency planning measures and detailed risk assessments are carried out in order to prevent loss of power. Furthermore, hospitals are legally required to ensure that systems must be reliable, available, maintainable and economic (in terms of efficiency).

Due to historically high levels of grid reliability, disruptions to electricity supplies are rare. To mitigate against loss of power, all healthcare premises are connected to the public electrical supply (PES), which is provided and operated by a local distribution network operator (DNO). It is recommended, where possible, that larger healthcare premises should be supplied with a dual PES from separate DNO substations. These, in turn, should ideally be fed from separate parts of the National Grid in order to avoid having a single point of mains failure.

In addition to a dual PES, hospitals are also equipped with emergency standby power generators, which are designed to offer significant power capacity in the event of a supply interruption or outage. 

Critical power

The increasing use of power-hungry devices within hospitals can result in electrical infrastructure running at full capacity. IT equipment, air conditioning and vital electronic diagnostic and monitoring medical equipment all require a constant supply of uninterruptible power. Without this, patient health is put at risk, particularly in departments such as operating theatres, cardiac wards, A&E and radiography, where life-support equipment is used. Non-clinical and support departments also rely on secure power supplies to maintain vital services and provide continuity of care.

Legal obligations, business continuity and reducing clinical and non-clinical risks are important reasons why a thorough resilience testing regime is essential for hospitals. Recent events in the US demonstrated how inadequate standby power contingency plans forced several hospitals and medical centres to close and evacuate patients following Hurricane Sandy.  In the UK, the failure of a 500 kVA standby power generator was caused by an excessive electrical load at Watford General Hospital in November 2004 .

Demand response

Recently, several NHS-run hospitals throughout the UK have improved their standby power resilience testing regimes through a programme called ‘demand response’ (DR). Demand response is an increasingly popular green alternative to the expensive carbon-heavy ‘peaking power stations’ that the National Grid relies on during times of grid stress.

The process involves electricity demand management whereby participants temporarily switch off or turn down non-essential power. Alternatively, companies can switch over to their existing independent standby power generators for a short period of time - usually around an hour. This reduces electricity use and helps National Grid to meet the needs of the country at times of grid stress without having to fire up expensive and dirty coal-fired power stations, or to import electricity from abroad.

Like a car engine, generators require frequent use to keep them working efficiently and, in order to ensure emergency preparedness, should be tested at least once a month. Testing ‘off-load’ can cause poor combustion, soot formation, clogging of injector rings and unburned fuel creating oil contamination.

Fuel kept in storage for extended periods of time can lead to further deterioration and damage. Demand response allows standby generators to be tested ‘on-load’ and at full capacity, making it an ideal way to prove engine resilience and optimise performance. Generators are most valuable in DR programmes where they are able to synchronise with the mains grid supply because they can support significant site electrical loads.

Recurring revenue

The National Grid is willing to pay organisations to use less electricity at times when it is struggling to meet peak demand. It is able to do this because it is cheaper than paying for polluting coal-fired power stations to be kept ‘warm’ or on standby in order to meet this occasional extra demand for energy.

Larger organisations, such as NHS-run hospitals, can earn up to £100,000 ($158,000) per year by participating in a DR programme with no upfront costs to pay. The installation of smart grid metering equipment and, if necessary, integration with existing building management systems, is carried out with no upfront cost by some DR aggregators such as KiWi Power.  

Increasing numbers of facility management staff working in hospitals are beginning to see the value of utilising their existing standby power assets for DR, or are incorporating DR measures when planning upgrades to electrical infrastructure.

Lister hospitalLister Hospital is an acute NHS-run hospital in Hertfordshire that is currently participating in a DR programme. The hospital recently upgraded its electrical systems, which included a new combined heat and power plant (CHP). To help ensure the hospital had a reliable standby power solution in the event of a power failure, it installed new on-site generators and duplicate electricity feeds.

Together with lower carbon CHP technology, Lister Hospital is provided with 4.5 MW which can be dispatched to provide short-term operating reserve (STOR) and is able to avoid peak energy tariffs through TRIAD management.

Demand response aggregator and smart grid company KiWi Power, was responsible for the project management and support for the deployment of four newly installed 2 MVA, LV diesel generators, which provide full back-up for a new 5 MVA, duplicate 11 kV feed from UK Power Networks. It also implemented a system for controlling and monitoring these generators remotely from its smart grid operations centre in London. Remote monitoring of the hospital’s standby power equipment allows facility managers to be contacted immediately should any problems arise.

Colchester Hospital University NHS Foundation Trust provides healthcare services to around 370,000 people from Colchester and the surrounding area of north-east Essex. Within one month of being awarded the contract, KiWi Power upgraded the electrical services and increased the load capacity of Colchester General Hospital. The DR programme allows a fully remote automated start from KiWi Power’s control room and has improved the Trust’s resilience testing regime, improved energy bill savings and generated a new revenue stream for the hospital.

Emissions control

A DR programme mitigates the risks associated with poorly managed backup energy supplies. The advantages of such a scheme are: costly load bank testing is reduced; an improvement in generator reliability at times of mains failure; hour-long run times so no alteration to generator cooling is required; and the replacement of a normal testing schedule with a revenue-generating load test exercise.

Through DR aggregators such as KiWi Power, hospitals are now reducing their energy consumption from the grid at peak demand times while getting paid by National Grid. In this way, hospitals are earning significant recurring revenue streams, gaining visibility into their real-time energy use, improving resilience testing regimes as part of their emergency preparedness and decreasing their carbon footprints.

Emerson Network Power new line for North American market

Tue, 01/29/2013 - 17:36 -- Anonymous
Share page with AddThis

Emerson Network Power has introduced three new models of the Liebert DSE, room-based data centre cooling systems. The 80kW, 85kW and 150kW units will join the current 125kW unit, will be available across North America.

data centre cooling

The Liebert DSE features the EconoPhase pumped refrigerant economiser that cools without the cost of water consumption or air contamination thus lowering operational costs.

The unit also features compressors to make the most of part-load efficiency, electronic expansion valves to support lower condensing temperatures, and variable speed electrically commutated plug fans that adjust the unit airflow to demand based on usage.

“The Liebert DSE represents the state-of-the-art in data centre room cooling and demonstrates that major increases in cooling efficiency can be achieved without compromising data centre reliability and performance,” said Steve Madara, Vice President, global cooling, Emerson Network Power. “These new models give data centre designers and managers more options to configure data centre cooling that is scalable, reliable and economical.”

Pages

Subscribe to backup power